78 research outputs found

    High performances monolithic CMOS detectors for space applications

    Get PDF
    During the last 10 years, research about CMOS image sensors (also called APS -Active Pixel Sensors) has been intensively carried out, in order to offer an alternative to CCDs as image sensors. This is particularly the case for space applications as CMOS image sensors feature characteristics which are obviously of interest for flight hardware: parallel or semi-parallel architecture, on chip control and processing electronics, low power dissipation, high level ofradiation tolerance... Many image sensor companies, institutes and laboratories have demonstrated the compatibility of CMOS image sensors with consumer applications: micro-cameras, video-conferencing, digital-still cameras. And recent designs have shown that APS is getting closer to the CCD in terms ofperformance level. However, the large majority ofthe existing products do not offer the specific features which are required for many space applications. ASTRI1JM and SUPAERO/CIMI have decided to work together in view of developing CMOS image sensors dedicated to space business. After a brief presentation of the team organisation for space image sensor design and production, the latest results of a high performances 512x512 pixels CMOS device characterisation are presented with emphasis on the achieved electro-optical performance. Finally, the on going and short-term coming activities of the team are discussed

    Development of high-performances monolithic CMOS detectors for space applications

    Get PDF
    This paper describes the development of a 750x750 pixels CMOS image sensor for star tracker applications. A first demonstrator of such a star tracker called SSM star tracker built around a 512x512 detector has been recently developed and proves the feasibility of such instrument. In order to take fully advantage of the CMOS image sensor step, the 750x750 device called SSM CMOS detector which will take part of the final star tracker, can be considered as a major technical breakthrough that gives a decisive advantage in terms of on satellite implementation cost and flexibility (sensor mass and power consumption minimisation, electronics and architecture flexibility). Indeed, built using the 0.5ÎĽm Alcatel Microelectronics standard CMOS technology, the SSM CMOS detector will feature on-chip temperature sensor and on-chip sequencer. In order to evaluate the radiation tolerance of such manufacturing technology, a radiation campaign that contains studies of total dose and latch-up effects has been led on a specific test vehicle

    Diagnostic ability of hand-held echocardiography in ventilated critically ill patients

    Get PDF
    STUDY OBJECTIVES: To compare the diagnostic capability of recently available hand-held echocardiography (HHE) and of conventional transthoracic echocardiography (TTE) used as a gold standard in critically ill patients under mechanical ventilation. DESIGN: A prospective and descriptive study. SETTING: The general intensive care unit of a teaching hospital. PATIENTS: All mechanically ventilated patients requiring a TTE study with a full-feature echocardiographic platform (Sonos 5500(®); Philips Medical Systems, Andover, MA, USA) also underwent an echocardiographic examination using a small battery-operated device (33 × 23 cm(2), 3.5 kg) (Optigo(®); Philips Medical Systems). INTERVENTIONS: Each examination was performed independently by two intensivists experienced in echocardiography and was interpreted online. For each patient, the TTE videotape was reviewed by a cardiologist experienced in echocardiography and the final interpretation was used as a reference diagnosis. RESULTS: During the study period, 106 TTE procedures were performed in 103 consecutive patients (age, 59 ± 18 years; Simplified Acute Physiology Score, 46 ± 14; body mass index, 26 ± 9 kg/m(2); positive end-expiratory pressure, 8 ± 4 cmH(2)O). The number of acoustic windows was comparable using HHE and TTE (233/318 versus 238/318, P = 0.72). HHE had a lower overall diagnostic capacity than TTE (199/251 versus 223/251 clinical questions solved, P = 0.005), mainly due to its lack of spectral Doppler capability. In contrast, diagnostic capacity based on two-dimensional imaging was comparable for both approaches (129/155 versus 135/155 clinical questions solved, P = 0.4). In addition, HHE and TTE had a similar therapeutic impact in 45 and 47 patients, respectively (44% versus 46%, P = 0.9). CONCLUSIONS: HHE appears to have a narrower diagnostic field when compared with conventional TTE, but promises to accurately identify diagnoses based on two-dimensional imaging in ventilated critically ill patients

    Diagnosis of left ventricular diastolic dysfunction in the setting of acute changes in loading conditions

    Get PDF
    International audienceINTRODUCTION: Conventional pulsed wave Doppler parameters are known to be preload dependent, whereas newly proposed Doppler indices may be less influenced by variations in loading conditions. The aim of the present study was to evaluate the effects of haemodialysis-induced preload reduction on both conventional and new Doppler parameters for the assessment of left ventricular (LV) diastolic function. METHODS: This prospective observational study was conducted in a medical-surgical intensive care unit (ICU) and nephrology department of a teaching hospital. In total, 37 haemodialysis patients with end-stage renal disease (age [mean +/- standard deviation]: 52 +/- 13 years) and eight ventilated ICU patients with acute renal failure receiving vasopressor therapy (age 57 +/- 16 years; Simplified Acute Physiology Score II 51 +/- 17) were studied. Echocardiography was performed before and after haemodialysis. Conventional pulsed wave Doppler indices of LV diastolic function as well as new Doppler indices, including Doppler tissue imaging early diastolic velocities (E' wave) of the septal and lateral portions of the mitral annulus, and propagation velocity of LV inflow at early diastole (Vp) were measured and compared before and after ultrafiltration. RESULTS: The volume of ultrafiltration was greater in haemodialysis patients than in ICU patients (3.0 +/- 1.1 l versus 1.9 +/- 0.9 l; P = 0.005). All conventional pulsed wave Doppler parameters were altered by haemodialysis. In haemodialysis patients, E' velocity decreased after ultrafiltration when measured at the septal mitral annulus (7.1 +/- 2.5 cm/s versus 5.9 +/- 1.7 cm/s; P = 0.0003), but not at its lateral portion (8.9 +/- 3.1 cm/s versus 8.3 +/- 2.6 cm/s; P = 0.37), whereas no significant variation was observed in ICU patients. Vp decreased uniformly after ultrafiltration, the difference being significant only in haemodialysis patients (45 +/- 11 cm/s versus 41 +/- 13 cm/s; P = 0.04). Although of less magnitude, ultrafiltration-induced variations in Doppler parameters were also observed in haemodialysis patients with altered LV systolic function. CONCLUSION: In contrast to other Doppler parameters, Doppler tissue imaging E' maximal velocity measured at the lateral mitral annulus represents an index of LV diastolic function that is relatively insensitive to abrupt and marked preload reduction

    Characterization of the boundary layer at Dome C (East Antarctica) during the OPALE summer campaign

    Get PDF
    The regional climate model MAR was run for the region of Dome C located on the East Antarctic plateau, during Antarctic summer 2011–2012, in order to refine our understanding of meteorological conditions during the OPALE observation campaign. A very high vertical resolution is set up in the lower troposphere, with a grid spacing of roughly 2 m. Comparisons are made with observed temperatures and winds near the surface and from a 45 m high tower as well as sodar and radiation data. MAR is generally in very good agreement with the observations but sometimes underestimates cloud formation, leading to an underestimation of the simulated downward long-wave radiation. Absorbed short-wave radiation may also be slightly overestimated due to an underestimation of the snow albedo and this influences the surface energy budget and atmospheric turbulence. Nevertheless the model provides sufficiently reliable information that represent key parameters when discussing the representativeness of chemical measurements made nearby the ground surface during field campaigns conducted at the Concordia site located at Dome C (3233 m a.s.l.)

    Assessment of Right Ventricular Mechanics by 3D Transesophageal Echocardiography in the Early Phase of Acute Respiratory Distress Syndrome

    Get PDF
    AIM: To compare global and axial right ventricular ejection fraction in ventilated patients for moderate-to-severe acute respiratory distress syndrome (ARDS) secondary to early SARS-CoV-2 pneumonia or to other causes, and in ventilated patients without ARDS used as reference. METHODS: Retrospective single-center cross-sectional study including 64 ventilated patients: 21 with ARDS related to SARS-CoV-2 (group 1), 22 with ARDS unrelated to SARS-CoV-2 (group 2), and 21 without ARDS (control group). Real-time three-dimensional transesophageal echocardiography was performed for hemodynamic assessment within 24 h after admission. Contraction pattern of the right ventricle was decomposed along the three anatomically relevant axes. Relative contribution of each spatial axis was evaluated by calculating ejection fraction along each axis divided by the global right ventricular ejection fraction. RESULTS: Global right ventricular ejection fraction was significantly lower in group 2 than in both group 1 and controls [median: 43% (25–75th percentiles: 40–57) vs. 58% (55–62) and 65% (56–68), respectively: p < 0.001]. Longitudinal shortening had a similar relative contribution to global right ventricular ejection fraction in all groups [group 1: 32% (28–39), group 2: 29% (24–40), control group: 31% (28–38), p = 0.6]. Radial shortening was lower in group 2 when compared to both group 1 and controls [45% (40–53) vs. 57% (51–62) and 56% (50–60), respectively: p = 0.005]. The relative contribution of right ventricular shortening along the anteroposterior axis was not statistically different between groups [group 1: 51% (41–55), group 2: 56% (46–63), control group; 56% (50–64), p = 0.076]. CONCLUSION: During early hemodynamic assessment, the right ventricular systolic function appears more impaired in ARDS unrelated to SARS-CoV-2 when compared to early stage SARS-CoV-2 ARDS. Radial shortening appears more involved than longitudinal and anteroposterior shortening in patients with ARDS unrelated to SARS-CoV-2 and decreased right ventricular ejection fraction

    Epinephrine Versus Norepinephrine for Cardiogenic Shock After Acute Myocardial Infarction

    Get PDF
    BACKGROUND Vasopressor agents could have certain specific effects in patients with cardiogenic shock (CS) after myocardial infarction, which may influence outcome. Although norepinephrine and epinephrine are currently the most commonly used agents, no randomized trial has compared their effects, and intervention data are lacking. OBJECTIVES The goal of this paper was to compare in a prospective, double-blind, multicenter, randomized study, the efficacy and safety of epinephrine and norepinephrine in patients with CS after acute myocardial infarction. METHODS The primary efficacy outcome was cardiac index evolution, and the primary safety outcome was the occurrence of refractory CS. Refractory CS was defined as CS with sustained hypotension, end-organ hypoperfusion and hyperlactatemia, and high inotrope and vasopressor doses. RESULTS Fifty-seven patients were randomized into 2 study arms, epinephrine and norepinephrine. For the primary efficacy endpoint, cardiac index evolution was similar between the 2 groups (p = 0.43) from baseline (H0) to H72. For the main safety endpoint, the observed higher incidence of refractory shock in the epinephrine group (10 of 27 [37%] vs. norepinephrine 2 of 30 [7%]; p = 0.008) led to early termination of the study. Heart rate increased significantly with epinephrine from H2 to H24 while remaining unchanged with norepinephrine (p <0.0001). Several metabolic changes were unfavorable to epinephrine compared with norepinephrine, including an increase in cardiac double product (p = 0.0002) and lactic acidosis from H2 to H24 (p <0.0001). CONCLUSIONS In patients with CS secondary to acute myocardial infarction, the use of epinephrine compared with norepinephrine was associated with similar effects on arterial pressure and cardiac index and a higher incidence of refractory shock. (Study Comparing the Efficacy and Tolerability of Epinephrine and Norepinephrine in Cardiogenic Shock [OptimaCC]; NCT01367743) (J AmColl Cardiol 2018; 72: 173-82) (C) 2018 by the American College of Cardiology Foundation.Peer reviewe

    Cardiac tamponade related to a coronary injury by a pericardial calcification: an unusual complication

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiac tamponade is a rare but severe complication of pericardial effusion with a poor prognosis. Prompt diagnosis using transthoracic echocardiography allows guiding initial therapeutic management. Although etiologies are numerous, cardiac tamponade is more often due to a hemopericardium. Rarely, a coronary injury may result in such a hemopericardium with cardiac tamponade. Coronary artery aneurysm are the main etiologies but blunt, open chest trauma or complication of endovascular procedures have also been described.</p> <p>Case presentation</p> <p>A 83-year-old hypertensive man presented for dizziness and hypotension. The patient had oliguria and mottled skin. Transthoracic echocardiography disclosed a circumferential pericardial effusion with a compressed right atrium, confirmed by contrast-enhanced thoracic CT scan. A pig-tail catheter allowed to withdraw 500 mL of blood, resulting in a transient improvement of hemodynamics. Rapidly, recurrent hypotension prompted a reoperation. An active bleeding was identified at the level of the retroventricular coronary artery. The pericardium was thickened with several "sharping" calcified plaques in the vicinity of the bleeding areas. On day 2, vasopressors were stopped and the patient was successfully extubated. Final diagnosis was a spontaneous cardiac tamponade secondary to a coronary artery injury attributed to a "sharping"calcified pericardial plaque.</p> <p>Conclusion</p> <p>Cardiac tamponade secondary to the development of a hemopericardium may develop as the result of a myocardial and coronary artery injury induced by a calcified pericardial plaque.</p
    • …
    corecore